Products Class
Products Your location:Home - Products -LH45X Flow Limiting Check Valve

LH45X Flow Limiting Check Valve

The LH45X flow limiting check valve supports the working point of the water pump to work within the area, limiting the operation of the water pump during high flow and low efficiency,at the same time, when the micro resistance slow closing check stops the pump, it closes without water hammer phenomenon; It can also prevent the motor from being burnt out due to overload rated current of the waterproof pump. It has an adjustable head function, with a limited head adjustable range of 0.1-0.6MPa, a pressure set at 0.1MPa, and an adjustable medium temperature between 0-150 ¡æ.

 

Working principle of LH45X flow limiting check valve:
The LH45X flow limiting check valve is installed at the outlet of the water pump, which limits the flow of the working pump during single pump startup and non design working pump operation, allowing the pump to operate in a relatively stable state; Prevent overloading of the electric motor during low head, high flow, and low efficiency of the water pump; Prevent the occurrence of motor burning due to rated current, while also playing a role in energy conservation. The flow limiting principle is based on the design operating point head of the water pump, and the LH45X flow limiting check valve automatically detects and controls the actual working head of the water pump to limit the working flow of the water pump and limit the load of the motor. The LH45X flow limiting check valve is set to control the working air head. When the working head of the water pump is lower than the control head, the valve will close to increase the actual working head; When the working head of the water pump is greater than the set head, the valve is fully open and the valve resistance is small. The setting of the control air head can be set according to the rated current of the motor or according to the operating conditions. The working head setting value of the valve is adjustable, and the general factory setting value is the design operating condition head.The check function of the LH45X flow limiting check valve is equivalent to a micro resistance slow closing check valve, with no back flow.

Technical parameters of LH45X flow limiting check valve

Nominal diameter

DN40-DN600

Nominal pressure

1.0Mpa

1.6Mpa

2.5Mpa

Applicable temperature

0¡æ~80¡æ

Shell test pressure

1.5Mpa

2.4Mpa

3.75Mpa

Sealing test pressure

1.1Mpa

1.76Mpa

2.75Mpa

Minimum operating pressure

P1¡Ý0.07MPa

Structural length standard

Q/BYL-2002

Flange length standard

GB/T 17241.6

Test pressure standard

GB/T 13927£»AP1598

 

LH45X Flow limiting check valve parts material

Valve body

Grey cast iron/ductile iron/cast steel/stainless steel

Valve cover

Grey cast iron/ductile iron/cast steel/stainless steel

Spring

Spring steel/stainless steel

Valve stem

2Cr13

Membrane

NBR nylon reinforced rubber/EPDM nylon reinforced rubber

Valve seat

Copper alloy/stainless steel

Disc

Grey cast iron/ductile iron/cast steel/stainless steel/copper

Diaphragm pressure plate

Grey cast iron/ductile iron/cast steel/stainless steel

O-type seal ring

NBR rubber/EPDM rubber

O-ring pressure plate

Grey cast iron/ductile iron/cast steel/stainless steel

 

External dimensions of LH45X flow limiting check valve

DN

40

50

65

80

100

125

150

200

250

300

350

400

450

500

600

L

200

203

216

241

270

292

330

400

480

550

622

685

750

811

935

H

225

225

270

289

375

420

450

722

769

906

1480

1027

1027

1110

1286

H1

137

137

145

178

232

286

318

413

502

600

638

677

677

750

850

Add:No.118,Wanyong Road,Langxia Town,Jinshan District,Shanghai,China