The D671X/D671J pneumatic wafer type soft seal butterfly valve product is composed of EPDM/NBR sealed butterfly valves,ductile iron or stainless steel valve plates, and valve stems. Suitable for regulating flow rate and intercepting medium on water supply and gas pipelines with a temperature ¡Ü 120 ¡æ,such as food, medicine, chemical, petroleum, electricity, light textile, paper making, etc. Adopting a new type of pneumatic actuator, there are double acting and single acting (spring return), gear transmission, safe and reliable; The large-diameter valve adopts a series of AW pneumatic actuators with a fork type transmission, with a reasonable structure and large output torque, available in double acting and single acting types.
Product features:
- The design is novel, reasonable, and has a unique structure, with light weight and fast opening and closing.
- Small operating torque, convenient operation, labor-saving and agile.
- Can be installed in any position, convenient for maintenance.
- The sealing element can be replaced, and the sealing performance is reliable, achieving zero leakage in both directions.
- The sealing material has characteristics such as aging resistance, corrosion resistance, and long service life.
Execution standards:
Design standard: GB/T12238-1989 JB/T8692-1998
Flange connection size: GB/T9115.1-2000
Structural length: GB/T12221-1989
Pressure test: GB/T13927-1992; JB/T9092-1999
Main performance parameter:
Performance parameters of D671X/D671J pneumatic wafer type soft seal butterfly valve |
Nominal diameter |
DN£¨mm£© |
50¡«2000 |
Nominal pressure |
PN£¨MPa£© |
0.6 |
1.0 |
1.6 |
Test pressure |
Strength test |
0.9 |
1.5 |
2.4 |
Seal test |
0.66 |
1.1 |
1.76 |
Gas seal test |
0.6 |
0.6 |
0.6 |
Applicable medium |
Air, water, sewage, steam, gas, oil etc. |
Drive form |
Manual, worm gear transmission, pneumatic transmission, electric transmission. |
Main parts material:
Materials of D671X/D671J Pneumatic Wafer Soft Seal Butterfly Valve Parts |
Parts name |
Material |
Valve body |
Ductile cast steel, cast steel, alloy steel, stainless steel |
Disc |
Gray cast iron, nodular cast steel, cast steel, stainless steel and special materials |
Sealing ring |
Various rubbers, PTFE |
Stem |
2Cr13,Stainless steel |
Filler |
O-ring, flexible graphite O |
Product external structural connection size:
The main external dimensions of D671X/D671J pneumatic wafer type soft seal butterfly valve |
Nominal diameter |
Structural length |
External dimensions (reference value) |
Connection size (standard value) |
0.6MPa |
1.0MPa |
1.6MPa |
mm |
in |
L |
L1 |
H |
H1 |
A |
D |
D1 |
n-d |
D |
D1 |
n-d |
D |
D1 |
n-d |
50 |
2 |
108 |
43 |
63 |
315 |
180 |
140 |
110 |
4-14 |
165 |
125 |
4-18 |
165 |
125 |
4-18 |
65 |
21/2 |
112 |
46 |
70 |
330 |
180 |
160 |
130 |
4-14 |
185 |
145 |
4-18 |
185 |
145 |
4-18 |
80 |
3 |
114 |
46 |
83 |
390 |
245 |
190 |
150 |
4-18 |
200 |
160 |
8-18 |
200 |
160 |
8-18 |
100 |
4 |
127 |
52 |
105 |
431 |
240 |
210 |
170 |
4-18 |
220 |
180 |
8-18 |
220 |
180 |
8-18 |
125 |
5 |
140 |
56 |
115 |
455 |
240 |
240 |
200 |
8-18 |
250 |
210 |
8-18 |
250 |
210 |
8-18 |
150 |
6 |
140 |
56 |
137 |
626 |
350 |
265 |
225 |
8-18 |
285 |
240 |
8-22 |
285 |
240 |
8-22 |
200 |
8 |
152 |
60 |
164 |
720 |
350 |
320 |
280 |
8-18 |
340 |
295 |
8-22 |
340 |
295 |
12-22 |
250 |
10 |
165 |
68 |
206 |
800 |
550 |
375 |
335 |
12-18 |
395 |
350 |
12-22 |
405 |
355 |
12-26 |
300 |
12 |
178 |
78 |
230 |
860 |
600 |
440 |
395 |
12-22 |
445 |
400 |
12-22 |
460 |
410 |
12-26 |
350 |
14 |
190 |
78 |
248 |
883 |
600 |
490 |
445 |
12-22 |
505 |
460 |
16-22 |
520 |
470 |
16-26 |
400 |
16 |
216 |
102 |
289 |
972 |
600 |
540 |
495 |
16-22 |
565 |
515 |
16-26 |
580 |
525 |
16-30 |
450 |
18 |
222 |
114 |
320 |
1043 |
750 |
595 |
550 |
16-22 |
615 |
565 |
20-26 |
640 |
585 |
20-30 |
500 |
20 |
229 |
127 |
343 |
1098 |
750 |
645 |
600 |
20-22 |
670 |
620 |
20-26 |
715 |
650 |
20-33 |
600 |
24 |
267 |
154 |
413 |
1236 |
750 |
755 |
705 |
20-26 |
780 |
725 |
20-30 |
840 |
770 |
20-36 |
700 |
28 |
430 |
165 |
478 |
1431 |
750 |
860 |
810 |
24-26 |
895 |
840 |
24-30 |
910 |
840 |
24-36 |
800 |
32 |
470 |
190 |
525 |
1488 |
750 |
975 |
920 |
24-30 |
1015 |
950 |
24-33 |
1025 |
950 |
24-39 |
900 |
36 |
510 |
203 |
620 |
1615 |
1250 |
1075 |
1020 |
24-30 |
1115 |
1050 |
28-33 |
1125 |
1050 |
28-39 |
1000 |
40 |
550 |
216 |
725 |
1765 |
1500 |
1175 |
1120 |
28-30 |
1230 |
1160 |
28-36 |
1255 |
1170 |
28-42 |
1200 |
48 |
630 |
254 |
780 |
1976 |
1500 |
1405 |
1340 |
32-33 |
1455 |
1380 |
32-39 |
1485 |
1390 |
32-48 |
Installation precautions:
- Before installation, the specifications, pressure, temperature, and corrosion resistance of the butterfly valve should be checked to ensure that they meet the requirements for use. Each component should be checked for damage or looseness.
- This butterfly valve can be installed on pipelines at any angle and should be closed for installation; When welding pipeline flanges, the valve sealing port should be blocked with a plate to prevent particles and debris from damaging the sealing surface. After welding, remove the valve, clean the valve sealing surface and pipeline cavity, and then install and fix the valve.
- Please pay attention to the pressure direction when installing when the valve is closed.
- Before installation, the sealing surfaces (sealing surfaces at both ends, butterfly plate sealing surfaces, and valve seat sealing surfaces) should be thoroughly wiped clean to remove dust and dirt.
- Before installation, the butterfly valve should be air tested, with flexible opening and closing, and the opening and closing positions should match the indicated positions of the pointer.
- Manually operate clockwise to close and counterclockwise to open. Do not apply force to open or close the valve after the pointer indicates it is in place.
- When conducting pressure tests on valves, it is not allowed to use a single flange for installation and pressure testing. Double flange installation and pressure testing must be used. The test pressure should comply with the provisions of GB/T13927-92 standard.
- When tightening bolts, they should be tightened symmetrically and alternately, and individual tightening in sequence is not allowed.
- The limit screw has been adjusted before leaving the factory and should not be easily adjusted. If the drive device is configured as electric or pneumatic, please refer to the accompanying drive device manual.
- The opening and closing stroke of the control mechanism has been adjusted when the electric butterfly valve leaves the factory. To prevent incorrect direction when the power is turned on, the user should manually turn it on to the half open position before the first power connection, then press the jog switch, and check that the direction of the indicator panel is consistent with the direction of the valve opening.
- If the valve is found to have abnormal opening and closing, the cause should be identified for repair and elimination to prevent damage to the valve caused by using force to open and close the valve.
|