Products Class
Products Your location:Home - Products -Manual Turbine Large Diameter Flange Butterfly Valve D341X/D342X/D343X

Manual Turbine Large Diameter Flange Butterfly Valve D341X/D342X/D343X

D341X/D342X/D343X manual turbine large-diameter flange butterfly valve is used at ¡Ü 120 ¡æ, with a nominal pressure of ¡Ü 1.6MPa. It is widely used in food, medicine, chemical, petroleum, electricity, light textile, paper and other water supply and drainage systems, as well as gas pipelines to regulate flow and intercept flow media.

Product features:

  1. The design is novel and reasonable, with a unique structure, light weight, and fast opening and closing.
  2. Small operating torque, convenient operation, labor-saving and agile.
  3. It can be installed and maintained conveniently in any position.
  4. The sealing element can be replaced, and the sealing performance is reliable, achieving zero leakage in both directions.
  5. The sealing material has characteristics such as aging resistance, corrosion resistance, and long service life.

Execution standards:
Design and manufacturing: GB/T12238
Structural length: GB12221-2005
Supply requirements: GB/T12252-2005
Pressure test: GB/T13927-2008
Pressure testing and inspection: GB/T13927-1992
Flange standard: GB/T9119-2010

Performance parameter:

Nominal diameter

DN mm

50¡«2000

Nominal pressure

PN MPa

0.6

1.O

1.6

Test pressure Ps MPa

Strength test

0.9

1.5

2.4

Sealing test

O.66

1.1

1.76

Applicable medium

Air, water, sewage, steam, gas, oil etc

Drive mode

Manual, worm gear transmission, pneumatic transmission, electric transmission

Main parts material:

Parts name

material

Valve body

Ductile iron, cast steel, alloy steel, stainless steel

Disc

Gray cast iron, ductile iron, cast steel, stainless steel and special materials

Sealing ring

Various rubber,PTFE

Stem

2Cr13,Stainless steel

 

Filler

O-ring, flexible graphite

Sealing material:

Material variety

Neoprene rubber

NBR

EPDM

PTFE

Silicon rubber

VITON

Code

¡Á 0rJ

XA or JA

XB or JB

xC¡¢JC 0r F

XD or JD

¡Á E or JE

Maximum temperature resistance

82¡æ

93¡æ

150¡æ

232¡æ

250¡æ

204¡æ

Minimum temperature resistance

-40¡æ

-40¡æ

-40¡æ

-268¡æ

-70¡æ

-23¡æ

Applicable working temperature

¡Ü65¡æ

¡Ü80¡æ

¡Ü120¡æ

¡Ü200¡æ

¡Ü200¡æ

¡Ü180¡æ

Product external structural connection size

Main connection dimensions of D341X/D342X/D343X manual turbine large-diameter flange butterfly valve

Diameter

Main size

0.6

1.0MPa

1.6MPa

mm

inch

L

H

H1

D

D1

Z-φd

D

D1

Z-φd

D

D1

Z-φd

80

3

114

115

235

185

150

4/18

195

160

4/18

195

160

8/18

100

4

127

120

240

205

170

4/18

215

180

8/18

215

180

8/18

125

5

140

130

270

235

200

8/18

245

210

8/18

245

210

8/18

150

6

140

150

300

260

225

8/18

280

240

8/23

280

240

8/23

200

8

152

180

300

315

280

8/18

335

295

8/23

335

295

12/23

250

10

250

220

400

370

335

12/18

390

350

12/23

405

355

12/25

300

12

270

250

410

435

95

12/23

440

400

12/23

460

410

12/25

350

14

290

270

460

485

445

12/23

500

460

16-23

520

470

16-25

400

16

310

290

510

435

495

16-23

565

515

16-25

585

525

16-30

450

18

330

320

560

500

550

20-23

615

565

20-25

640

585

20-30

500

20

350

360

590

640

600

20-23

670

620

20-25

705

650

20-34

600

24

390

390

660

755

705

20-25

780

725

20-30

840

770

20-41

700

28

430

460

780

860

810

24-25

895

840

24-30

910

840

24-41

800

32

470

530

850

975

920

24-30

1010

950

24-34

1020

950

24-41

900

36

510

570

920

1075

1020

24-30

1110

1050

28-34

1120

1050

28-41

1000

40

550

630

990

1175

1120

28-30

1220

1160

28-34

1255

1170

28-48

1200

48

630

750

1115

1400

1340

32-34

1450

1380

32-41

1485

1390

32-54

1400

56

710

850

1228

1375

1320

32-30

 

 

 

 

 

 

1620

1560

36-34

1675

1590

36-48

 

 

 

1600

64

790

990

1340

1575

1520

36-40

 

 

 

 

 

 

1820

1760

40-34

1915

1820

40-54

 

 

 

1800

72

870

110

1570

1785

1730

40-30

 

 

 

 

 

 

2045

1970

44-41

2115

2020

44-54

 

 

 

2000

80

950

1170

1680

1985

1930

44-30

 

 

 

 

 

 

2265

2180

48-48

2325

2230

46-54

 

 

 

Installation precautions:

  1. Before installation, the specifications, pressure, temperature, and corrosion resistance of the butterfly valve should be checked to ensure that they meet the requirements for use. Each component should be checked for damage or looseness.
  2. This butterfly valve can be installed on pipelines at any angle and should be closed for installation; When welding pipeline flanges, the valve sealing port should be blocked with a plate to prevent particles and debris from damaging the sealing surface. After welding, remove the valve, clean the valve sealing surface and pipeline cavity, and then install and fix the valve.
  3. Please pay attention to the pressure direction when installing when the valve is closed.
  4. Before installation, the sealing surfaces (sealing surfaces at both ends, butterfly plate sealing surfaces, and valve seat sealing surfaces) should be thoroughly wiped clean to remove dust and dirt.
  5. Before installation, the butterfly valve should be air tested, with flexible opening and closing, and the opening and closing positions should match the indicated positions of the pointer.
  6. Manually operate clockwise to close and counterclockwise to open. Do not apply force to open or close the valve after the pointer indicates it is in place.
  7. When conducting pressure tests on valves, it is not allowed to use a single flange for installation and pressure testing. Double flange installation and pressure testing must be used. The test pressure should comply with the provisions of GB/T13927-92 standard.
  8. When tightening bolts, they should be tightened symmetrically and alternately, and individual tightening in sequence is not allowed.
  9. The limit screw has been adjusted before leaving the factory and should not be easily adjusted. If the drive device is configured as electric or pneumatic, please refer to the accompanying drive device manual.
  10. The opening and closing stroke of the control mechanism has been adjusted when the electric butterfly valve leaves the factory. To prevent incorrect direction when the power is turned on, the user should manually turn it on to the half open position before the first power connection, then press the jog switch, and check that the direction of the indicator panel is consistent with the direction of the valve opening.
  11. If the valve is found to have abnormal opening and closing, the cause should be identified for repair and elimination to prevent damage to the valve caused by using force to open and close the valve.

 

Add:No.118,Wanyong Road,Langxia Town,Jinshan District,Shanghai,China
Tel: +86 (021) 57392292 57392293
E-mail:rayhan@zhvalve.com
Web:www.zhvalve.com
Copyright © 2023 Shanghai Zhonghang Valve Co., Ltd. All Rights Reserved.