Products Class
Products Your location:Home - Products -Q347F/H Manual Turbine Fixed Flange Ball Valv

Q347F/H Manual Turbine Fixed Flange Ball Valv

Compared with floating ball valves, Q347F turbine fixed ball valves transmit all the force generated by the fluid pressure in front of the valve on the ball to the bearing during operation, which does not cause the ball to move towards the valve seat. Therefore, the valve seat will not bear excessive pressure, resulting in small torque, small valve seat deformation, stable sealing performance, and long service life of fixed ball valves. They are suitable for high-pressure and large-diameter situations. Advanced spring pre seat components with self tightening characteristics, achieving upstream sealing. Manual turbine, flange connection, fixed structural form, valve body made of carbon steel or stainless steel material, sealed with internal PTFE valve seat or alloy material, used at a temperature of -29 ¡æ+350 ¡æ, selected according to the sealing material, suitable for medium: water, oil, gas, chemical gas and liquid, with a pressure of 1.0MPa~6.4MPa. It is widely used in natural gas, electricity, metallurgy, chemical industry, shipbuilding, paper making, food, aerospace, petroleum and other heavy and light industries. Suitable for industries such as chemical, petroleum, natural gas, metallurgy, as well as natural gas long-distance pipelines containing hydrogen sulfide media, impurities, and severe corrosion.

Product features:

  1. The valve seat adopts a spring structure, which pushes the valve seat towards the sphere, ensuring good low-pressure sealing performance;
  2. Both the front and back valve seats of the fixed ball valve can be sealed, which is known as the bidirectional sealing feature. By using the built-in discharge valve, the middle chamber of the valve body can discharge outward;
  3. The pivot adopts an anti blow out protection structure and low friction coefficient bearings. Has excellent performance, high reliability, and a wide range of applications;

Execution standards:
Design and manufacturing: GB/T12237-2007
Structural length: GB12221-2005
Supply requirements: GB/T12252-2005
Pressure test: GB/T13927-2008
Pressure testing and inspection: GB/T13927-1992
Thread standard: G·NPT BSPT BSP DIN259/2999

Product performance parameter:

Performance parameters of Q347F turbine fixed ball valve

Pressure rating£¨MPa£©

1.6

2

4

6.4

Valve strength testing pressure£¨MPa£©

2.4

3

6

9.6

Valve sealing test pressure£¨MPa£©

1.76

2.2

4.4

7.04

Applicable temperature¡æ

©20¡æ¡«350¡æ

Main material

High quality carbon steel

Connection form

Flange

Opening and closing form

Manual turbine

Applicable medium

Water,gas,oil

Connection standard

GB9113/JB79


Product external structure connection size:

 

External Connection Dimensions of Q347F Turbine Fixed Ball Valve

Nominal diameter

Main external dimensions and connection dimensions

L

D

D1

D2

b

Z-d

H

H1

D0

50

178

160

125

100

16

4-18

160

85

-

65

191

180

145

120

18

4-18

170

95

-

80

206

195

160

135

20

8-18

200

110

-

100

229

215

180

155

20

8-18

210

120

-

125

356

245

210

185

22

8-18

350

215

-

150

394

280

240

210

24

8-23

530

190

-

200

457

335

295

265

26

12-23

575

230

600

250

533

405

355

320

30

12-25

585

260

600

300

610

460

410

375

30

12-25

730

300

600

350

686

520

470

435

34

16-25

860

350

800

400

762

580

525

485

36

16-30

935

395

800

450

864

640

585

545

40

20-30

975

440

800

500

912

705

650

608

44

20-34

1060

485

800

600

1067

840

770

718

48

20-41

1170

591

800

700

1245

910

840

788

50

24-41

1270

686

800

Installation precautions for ball valves:

  1. During installation and construction, care must be taken to avoid hitting the valve.
  2. Before installation, the ball valve should be inspected to verify its specifications and model, and to identify any damage, especially for the valve stem. Rotate it a few more times to see if it is skewed, as the valve stem is most likely to be knocked off during transportation. Also, remove any debris inside the valve.
  3. When lifting a ball valve, the rope should not be tied to the handwheel or valve stem to avoid damaging these components. It should be tied to the valve body.
  4. The pipeline connected to the ball valve must be cleaned thoroughly. Compressed air can be used to blow away iron oxide shavings, mud and sand, welding slag, and other debris. These debris not only easily scratch the sealing surface of the ball valve, but also block the small valve with large particles (such as welding slag), causing it to fail.
  5. Leave a position for the valve handle to rotate during installation.
  6. Ball valves cannot be used for throttling.